Explosion protection marking |
PB Ex mb [ia Ma] I Mb X / PO Ex ia I Ma* |
| Operating temperature, °C | from 0 to +50 |
| Ingress protection rating | IP65 |
| Protection class against electric shock | I |
| Rated supply voltage, V** |
127 / 220 / 380 / 660 |
| Battery type | LiFePO4 |
| Battery capacity, Wh | 900 |
| Rated output voltage of intrinsically safe DC supply, V | 12 |
| Power supply features | 2 inputs (ATS function) |
|
Number of intrinsically safe power output channels** I0 = 2.0 A |
2 |
|
Rated output current, A** |
2.0 / 3.5 |
|
Rated DC output voltage at rated current, V |
12 |
| Diagnostics and control |
Data exchange via RS-485 interface (Modbus) Discrete signals (functional purpose programmable by user) Input signal (DI) – 1 pc. Output signals (DO) – 4 pcs. LED indication Door opening monitoring function |
|
Length of permanently connected power cables, m, not less than |
2 x 2 pcs. |
| Diameter of connected cables for intrinsically safe circuits, mm | from 9 to 13 |
|
Overall dimensions, mm |
450 x 410 x 180 |
|
Weight, kg |
35 |
|
Service life, years |
10 |
* - when disconnected from the power supply (e.g. in emergency situations), the explosion protection marking is PO Ex ia I Ma
** - depending on the version
Application area
Underground mine workings, pits, and their surface structures, including those hazardous due to gas and/or dust, in accordance with explosion protection marking and industry safety regulations.