Explosion protection marking: Version IIP–M2–40–U0–I01–I02–Ex Version IIP–M2–40–U0–I01–I02–Exd |
PB Ex mb [ia Ma] I Mb X / PO Ex ia I Ma*; PB Ex d mb [ia Ma] I Mb X / PO Ex ia I Ma* |
| Operating temperature, °C | from –20 to +40 |
| Ingress protection rating | IP65 |
| Protection class against electric shock | I |
| Rated supply voltage, V | 127 / 220 |
| Maximum power consumption from AC mains, W | 250 |
| Power supply frequency (main input), Hz | 50 |
| Battery charging current, A | 4 |
| Battery capacity, Ah | 40 |
| Number of charge-discharge cycles, pcs. | up to 600 at 60% depth of discharge |
| Rated DC output voltage, V | 12; 13.8 (depending on version) |
| Maximum deviation of output voltage from rated value, % | ±10 |
| Output voltage ripple level (ripple class VR3), V, not more than | 0.2 (5%) |
| Number of intrinsically safe output channels (galvanically isolated) | 2 |
|
Rated output current, A** Maximum output current, A** |
0.85 / 1.85 1.0 / 2.0 |
| Output opto-relays (“dry contact” type) | Output 1 / Output 2 / Mains / Low battery / Fault |
| Technical readiness time, s, not more than | 5 |
|
Length of permanently connected power cable, m, not less than Version IIP–M2–40–U0–I01–I02–Ex*** |
3 |
|
Overall dimensions, mm: Version IIP–M2–40–U0–I01–I02–Exd Version IIP–M2–40–U0–I01–I02–Ex (excluding permanently connected cable) |
620 x 265 x 250; 465 x 265 x 250 |
|
Weight, kg: Version IIP–M2–40–U0–I01–I02–Ex Version IIP–M2–40–U0–I01–I02–Exd |
40; 45 |
| Diagnostics and control |
RS-485 (Modbus) – 1 pc.; Output opto-relays (Output 1 / Output 2 / Mains / Low battery / Fault) – 5 pcs.; LED indication |
* – when disconnected from the mains (e.g. in emergency situations), the explosion protection marking is PO Ex ia I Ma;
** – maximum output currents of IIP channels (depending on version);
*** – parameter values are given for the standard configuration and may be specified when ordering, without affecting the explosion protection of the product.
Application area
Underground mine workings, pits, and their surface structures, including those hazardous due to gas and/or dust, in accordance with explosion protection marking and industry safety regulations.